Turbidity Meter-Lutron TU-2016 Made in Taiwan
- Designed to meet ISO 7027.
- NTU ( Nephelometric TURBIDITY Unit ) measuring unit.
- Wide and auto measurement range : 0 to 1,000 NTU.
- High resolution: 0.01 NTU/1 NTU.
- The unique optics structure enables the instrument to read the low value of TURBIDITY to the high level up to 1,000 NTU.
- Four operation buttons and two calibration points, easy operation.
- Jumbo LCD, easy readout.
- The microprocessor circuit assures maximum possible accuracy and provides special functions and features.
- Battery operated for field and on-site testing convenience.
- Data hold function for freezing the desired value on the display.
- Records Maximum and Minimum readings with Recall.
- Heavy-duty & compact housing with a hard carrying case, designed for easy carry out & operation.
- Auto shut-off is available to save battery life.
- Application: Test municipal water, food, and beverage water, or other aqueous solution where fluid clarity is important.
SPECIFICATIONS
- Circuit: Custom one-chip of microprocessor LSI circuit.
- Display LCD size : 41 mm x 34 mm
- Range: 0.00 to 50.00 NTU, 50 to 1,000 NTU
- NTU: Nephelometric Turbidity Unit
- Auto range
- Resolution 0.01 NTU/ 1 NTU
- Accuracy ± 5 % F.S. or ± 0.5 NTU, whichever is greater.
- Light source LED, 850 nm.
- Detector Photodiode
- Standard Meet ISO 7027.
- Response time Less than 10 seconds.
- Sample volume needed 10 mL.
- Data Hold Freeze the display reading.
- Memory Recall Maximum & Minimum value.
- Display Sampling Time Approx. 1 second.
- Power off Auto shut off saves battery life or manual off by push button.
- Calibration points 0 NTU, 100 NTU.
- Operating Temperature 0 to 50℃
- Operating Humidity Less than 85% R.H.
- Power Supply DC 1.5 V battery ( UM4, AAA ) x 6 PCs, or equivalent.
- Power Current Stand by Approx. DC 3.5 mA.
- Testing Approx. DC 36 mA.
- Weight 320 g/0.70 LB. @ Battery is included.
- Dimension 155 x 76 x 62 mm ( 6.1 x 3.0 x 2.4 inch)
- Accessories Testing bottle with 0 NTU standard solution………….1 PC
- Included Testing bottle with 100 NTU standard solution……… 1 PC
- Empty testing bottle……………………………………….. 2 PCs
- Clean cloth…………………………………………………….1 PC
- Clean solution ( Distill water )…………………………….1 bottle
- Hard carrying case, CA-08…………………………………1 PC
- Optional Accessories
- Testing bottle with 100 NTU standard solution, TU-100NTU
- Testing bottle with 0 NTU standard solution, TU-0NTU
- Empty testing bottle, 0601