Description
UNI-T UT890C RMS Multimeter With Temperature Tester. The UT890 series 6000-count true RMS digital multimeters are designed with a large LCD. The maximum measurable capacitance is 100mF, with a fast response time of less than 12s. The NCV and continuity measurement have acousto-optic indications. UT890C or UT890D+ has a LIVE function for distinguishing between live and neutral wires. In addition, it is equipped with automatic fuse blown detection and high voltage protection. Models in UT890 Series: UT890C, UT890D+
Features of UT890C Digital True RMS Multimeter
- Manual range/True RMS
- Data hold/REL
- Audible/visual alarm (NCV/continuity)
- Current (AC/DC) mode memory
- Low battery indication: ≤2.5V
- NCV/hFE/Max/Min
- Diode test/Continuity test
- High voltage false detection: 1000Vrms
- Over-current alarm: ≥20A
- Auto power off/LCD backlight
Specifications of UT890 Series Digital True RMS Multimeters
Specification | Range | UT890C | UT890D+ |
DC Voltage | 600mV/6V/60V/600V/1000V | ±(0.5%+2) | ±(0.5%+2) |
AC Voltage | 6V/60V/600V/750V | ±(0.8%+3) | ±(0.8%+3) |
ACV Frequency | 10Hz~10kHz | ±(0.1%+5) | ±(0.1%+5) |
DC Current | 60uA//600uA/6mA/60mA/600mA/20A | ±(0.8%+8) | ±(0.8%+8) |
AC Current | 60uA/600uA/6mA/60mA/600mA/20A | ±(1%+12) | ±(1%+12) |
Resistance | 600Ω/6kΩ/60kΩ/600kΩ/6MΩ/60MΩ | ±(0.8%+3) | ±(0.8%+3) |
Capacitor | 6.000nF/60.00nF/600.0nF/6.000μF/60.00μF/ 600.0μF/6.000mF/60.00mF/100.0mF | ±(3%+10) | ±(3%+10) |
Frequency | 9.999Hz~9.999MHz | ±(1.0%+5) | ±(1.0%+5) |
Temperatue | –40℃~1000℃/–40°F~1832°F | ±(1.5%+5) | |
Features | |||
Display Count | 6000 | 6000 | |
Manual Range | √ | √ | |
NCV | √ | √ | |
hFE | √ | √ | |
Diode Test | √ | √ | |
Continuity Test | √ | √ | |
Live | √ | ||
True RMS | √ | √ | |
Fuse blowing alarm | √ | √ | |
Acousto-optic indication(NCV/continuity) | √ | √ | |
High voltage false detection | 1000Vrms | √ | √ |
Current (AC/DC) mode memory | √ | √ | |
Over-current alarm | ≥20A | √ | √ |
Low Battery Indication | ≤2.5V | √ | √ |
Data Hold | √ | √ | |
REL | √ | √ | |
Max/Min | V 、A | √ | √ |
Auto Power Off | 15Min | √ | √ |
Backlight | The 30s | √ | √ |
Operation Temperature | 0℃~40℃ | ||
Safety | CAT II 1000V/CAT III 600V | ||
General Characteristics | |||
Power | 1.5V x 2 | ||
Product Color | Red and Gray | ||
Product Net Weight | 346g | ||
Product Size | 183mm x 88mm x 56mm | ||
Standard Individual Packing | Gift Box, Manual | ||
Standard Quantity Per Carton | 40pcs | ||
Standard carton measurement | 690mm x 450mm x 340mm | ||
Standard carton gross weight | 23Kg |
Applications of UT890 Series True RMS Multimeter
- Live and nature wires identification
- Voltage measurement
- Temperature measurement
- NCV measurement
- and many more.